1. What type of grease do we put in the pump and motor bearings?
- Polyurea Base No. 2 Grease
-
-
2. How hot can the pump bearings operate?
- Maximum to 180 degrees F - Normal 130 degrees to 140 degrees
F
-
-
3. What is the wear ring clearance?
- 009" to .011" on a side or .018" to .022"
diametrically
-
-
4. What is the coupling alignment tolerance?
- .005" or below
-
-
5. What is an acceptable skin temperature for the motor?
- 250 degrees F
-
-
6. Do we need flush lines on the seals or packing?
- Yes, When pumping gritty water or operating on suction lift
Back to Top